Home
In-situ electron microscopy
TEM in-situ solutions
Spring Series In-Situ Holders
Breeze Series In-Situ Holders
Volcano Series In-Situ Holders
Gravity Series In-Situ Holders
Glacier Series Holders
Accessories Series
Consumable Series
SEM in-situ solutions
Spring Series In-Situ Stages
Breeze Series In-Situ Stages
Volcano Series In-Situ Stages
Gravity Series In-Situ Stages
Glacier Series Stages
Others
Single-Tilt Tomography Holders
On-Axis Rotation Tomography Holders(Automatic Full Angle)
Multiple Samples Holders(4 Holes)
Air-Free Transfer holders
Double-tilt Holders(GRID)
SEM Vacuum Transfer Chamber
High Vacuum Storage Instrument for Sample Holders
Case
Liquid electrochemistry
catalytic
Nano Materials
Metal Materials
Crystal growth
New Energy
About CHIPNOVA
Company Profile
About Us
Corporate Culture
Development History
Corporate Governance
Qualifications and Honors
News
Company News
Exhibition Events
Industry news
Result sharing
Contact Us
Contact information
Consulting Quotes/Programs
EN
Chinese
English
Gravity Series In-Situ Holders(Biasing&Double Tilt)
Gravity Series In-Situ Holders(Biasing&Double Tilt) is used to control the electric field of the sample,combining with EDS,EELS,SAED,HRTEM,STEM and other different modes,The key information such as microstructure evolution,phase transition,elemental valence state,microscopic stress,and surface/interface structure and composition evolution of samples under vacuum environment can be monitored in real time and dynamically at the nano level。
Gravity Series In-Situ Holders(Straining&Single Tilt)
The rod body is made of high strength titanium alloy material to avoid the bending deformation of the rod body during long-term use; The sample rod uses Axis design, built-in high precision reduction gear, stretching step better than 100nm, good straightness of motion. The rectangular opening at the tip of the sample rod has a fastening point at each end, one end is a fixed mounting point, and the other end is a movable cross head, which can securely fix the sample in the corresponding position during the tensile and compression process.
Gravity Series In-Situ Holders(Nano Indentation&Heating&Biasing)
Gravity Series In-Situ Holders(Nano Indentation&Heating&Biasing)applies mechanics, electric field and thermal field to the sample through MEMS chip.The construction of force, electrical, thermal composite multi-field automatic control and feedback in the in-situ sample station Measurement system, combined with EDS, EELS, SAED, HRTEM, STEM and other different modes,realizes real-time and dynamic monitoring of samples in vacuum with temperature, electric field and application at the nano level microstructure evolution, phase transition, elemental valence state, microscopic stress and surface/boundary resulting from afterforce changes Key information such as the structure and composition evolution .
Gravity Series In-Situ Holders(Nano Indentation&Heating)
Gravity Series In-Situ Holders(Nano Indentation&Heating) was constructed by MEMS chip in the in-situ.Mechanical and thermal composite multi-field automatic control and feedback measurement system, combined with EDS, EELS, SAED,HRTEM, STEM and other different modes can realize real-time and dynamic sample monitoring from the nano level Microstructure evolution, phase change and element change with temperature and applied force in vacuum environment Key information such as prime valence states, microscopic stresses, and structural and compositional evolution at the surface/interface.
Gravity Series In-Situ Holders(Nano Indentation&Biasing)
The Gravity Series In-Situ Holders(Nano Indentation&Biasing) was constructed by MEMS chip in the in-situ sample station. Mechanical and thermal composite multi-field automatic control and feedback measurement system, combined with EDS, EELS, SAED,HRTEM, STEM and other different modes can realize real-time and dynamic sample monitoring from the nano level Microstructure evolution, phase change and element change with temperature and applied force in vacuum environment Key information such as prime valence states, microscopic stresses, and structural and compositional evolution at the surface/interface.
Volcano Series In-Situ Holders(Ultra Heating&Single Tilt)
The tungsten wire is used to make the heating module, which has the advantages of 1500 ° C ultra-high temperature, easy replacement of the heating module, and low sample preparation cost.
Volcano Series In-Situ Holders (Optics&Biasing&Double Tilt)
Optical fiber and MEMS chip are used to construct an optical and biasing composite multi-field automatic control and feedback measurement system in the in-situ sample stage.Combined with EDS, EELS,SAED,HRTEM,STEM and other different modes, the key information such as microstructure evolution, phase transition,elemental valence state,microscopic stress and atomic structure and composition evolution at the surface/interface of the sample under vacuum environment can be monitored in real time and dynamically from the nano or even atomic level with the change of light field and temperature.
Volcano Series In-Situ Holders (Optics&Heating&Double Tilt)
Volcano Series In Situ Holders (Optics&Heating&Double Tilt) construct an optical and biasing composite multi field automatic control and feedback measurement system in an in-situ sample stage using a light source introduced by optical fibers and MEMS chips. By combining multiple different modes such as EDS, EELS, SAED, HRTEM, STEM, etc., real-time and dynamic monitoring of the microstructure evolution, phase transition, and elemental valence states of the sample under vacuum environment with changes in light field and temperature can be achieved at the nanoscale or even atomic level Key information such as microstresses and atomic level structure and composition evolution at the surface/interface.